LWOPlatform moves its object with SetPosition and SetRotation ignoring the dirty flags (ProcessStateChange 0x00cce380), turned between the two waypoints' rotations, and live serialized a moving platform's mover data without its physics. The server's object stayed where it spawned, so anything that asks where a platform is (the lightning orbs' knockback of issue 1352, phantoms riding a platform) had the start of its path.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The state bits were named the wrong way round: 1 is waiting and 4 is stopped (LWOPlatform::StartTravelling 0x0058b170, StopTravelling 0x0058b1d0), and the client only stops on 4 (LWOPlatform::Deserialize 0x00c870e0), so a mover stopped on its way kept moving on the client. The mover now runs as LWOPlatform::RunPlatform 0x00c86e10, ArrivedAtWaypoint 0x00c86c30, HandleWaypointArrived 0x00c17bc0 and ResumeTravelling 0x00c86b90, which gives the states of the live captures: 12 until started, 9 waiting at a waypoint (25 at an end), 2 on its way, 28 stopped at an end of a path run once. A GoToWaypoint at a waypoint waits there first with the desired waypoint, as the NJ falling tiles did, and a mover that stops is not serialized for it. A quick build's mover does not run until it is built.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
PlatformSubComponent (LWOPlatform: the state between waypoints and its
serialization) is the base of MoverSubComponent (4), SimpleMoverSubComponent
(5) and the new RotatorSubComponent (6), as LWOPlatformMover,
LWOPlatformSimpleMover and LWOPlatformRotator are built on LWOPlatform. The
platform keeps one subcomponent per type the client makes
(LWOMovingPlatformComponent::SetupPlatform: one per platformIs* setting that
is true) and sends them all; the first is the one the server runs. Same bytes
for every platform with one subcomponent.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Components get the client's per-component functions: LoadDataFromTemplate,
PrepareConfigData, LoadConfigData, LoadFromSaveData, Startup, Run,
OnEnterScope, OnLeaveScope, Preshutdown and Shutdown, called by the entity in
the client's order. Update is renamed Run, LoadFromXml LoadFromSaveData and
UpdateXml WriteSaveData. Nothing sent changes.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
LWOPlatform::ResumeTravelling: not travelling at a waypoint it waits the waypoint's wait; the AG monument elevator rose at once.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The client's LWOPlatform logic (ArrivedAtWaypoint 0x00c86c30, ProcessStateChange 0x00cce380, GetNextWaypoint, the waypoint speeds) runs on the server: stopped at a waypoint (25 at an end) for its wait, then travelling (2), serialized on arrival and departure as in the NT mover captures; constructions carry the path and the mover state; RequestPlatformResync gets the current state, percent and position. The LOT 9483 timers are gone.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>