rmm-scripts/fan_control.sh
2024-08-10 12:03:21 -07:00

91 lines
3.1 KiB
Bash
Executable File

#!/bin/bash
#
# A fork of brezlord's fan control script. https://github.com/brezlord/iDRAC7_fan_control
# A simple script to control fan speeds on Dell generation 12 PowerEdge servers.
# If the inlet temperature is above $TEMP_THRESHOLD C enable iDRAC dynamic control and exit program.
# If inlet temp is below $TEMP_THRESHOLD C set fan control to manual and set fan speed to predetermined value.
# The tower servers T320, T420 & T620 inlet temperature sensor is after the HDDs so temperature will
# be higher than the ambient temperature.
# Variables
IDRAC_IP=""
IDRAC_USER=""
IDRAC_PASSWORD=""
# Fan speed in %
SPEED0="0x00"
SPEED5="0x05"
SPEED10="0x0a"
SPEED15="0x0f"
SPEED20="0x14"
SPEED25="0x19"
SPEED30="0x1e"
SPEED35="0x23"
TEMP_THRESHOLD="45" # iDRAC dynamic control enable thershold
#TEMP_SENSOR="04h" # Inlet Temp
TEMP_SENSOR="01h" # Exhaust Temp
#TEMP_SENSOR="0Eh" # CPU 1 Temp
#TEMP_SENSOR="0Fh" # CPU 2 Temp
SENSOR_NAME="Sensor"
if [ "$TEMP_SENSOR" == "04h" ]
then
SENSOR_NAME="Inlet"
elif [ "$TEMP_SENSOR" == "01h" ]
then
SENSOR_NAME="Exhaust"
elif [ "$TEMP_SENSOR" == "0Eh" ]
then
SENSOR_NAME="CPU1"
elif [ "$TEMP_SENSOR" == "0Fh" ]
then
SENSOR_NAME="CPU2"
fi
# Get system date & time.
DATE=$(date +%d-%m-%Y\ %H:%M:%S)
echo "Date $DATE"
# Get temperature from iDARC.
T=$(ipmitool -I lanplus -H $IDRAC_IP -U $IDRAC_USER -P $IDRAC_PASSWORD sdr type temperature | grep $TEMP_SENSOR | cut -d"|" -f5 | cut -d" " -f2)
echo "--> iDRAC IP Address: $IDRAC_IP"
echo "--> Current $SENSOR_NAME Temp: $T"
# If ambient temperature is above $TEMP_THRESHOLD C enable dynamic control and exit, if below set manual control.
if [[ $T > $TEMP_THRESHOLD ]]
then
echo "--> Temperature is above $TEMP_THRESHOLD C"
echo "--> Enabled dynamic fan control"
ipmitool -I lanplus -H $IDRAC_IP -U $IDRAC_USER -P $IDRAC_PASSWORD raw 0x30 0x30 0x01 0x01
exit 1
else
echo "--> Temperature is below $TEMP_THRESHOLD C"
echo "--> Disabled dynamic fan control"
ipmitool -I lanplus -H $IDRAC_IP -U $IDRAC_USER -P $IDRAC_PASSWORD raw 0x30 0x30 0x01 0x00
fi
# Set fan speed dependant on ambient temperature if inlet temperaturte is below $TEMP_THRESHOLD C.
# If inlet temperature between 0 and 19deg C then set fans to 15%.
if [ "$T" -ge 0 ] && [ "$T" -le 19 ]
then
echo "--> Setting fan speed to 15%"
ipmitool -I lanplus -H $IDRAC_IP -U $IDRAC_USER -P $IDRAC_PASSWORD raw 0x30 0x30 0x02 0xff $SPEED15
# If inlet temperature between 20 and 24deg C then set fans to 20%
elif [ "$T" -ge 20 ] && [ "$T" -le 24 ]
then
echo "--> Setting fan speed to 20%"
ipmitool -I lanplus -H $IDRAC_IP -U $IDRAC_USER -P $IDRAC_PASSWORD raw 0x30 0x30 0x02 0xff $SPEED20
# If inlet temperature between 25 and 29deg C then set fans to 25%
elif [ "$T" -ge 25 ] && [ "$T" -le 29 ]
then
echo "--> Setting fan speed to 25%"
ipmitool -I lanplus -H $IDRAC_IP -U $IDRAC_USER -P $IDRAC_PASSWORD raw 0x30 0x30 0x02 0xff $SPEED25
# If inlet temperature between 30 and $TEMP_THRESHOLD C then set fans to 30%
elif [ "$T" -ge 30 ] && [ "$T" -le $TEMP_THRESHOLD ]
then
echo "--> Setting fan speed to 25%"
ipmitool -I lanplus -H $IDRAC_IP -U $IDRAC_USER -P $IDRAC_PASSWORD raw 0x30 0x30 0x02 0xff $SPEED25
fi