Zeb Hering 9961e972df Move the shelf ramp above the drives' working range, add a deadband
Retiring 8x2TB for 4x8TB + a 16TB moved the hottest drive to 40-41c,
exactly the old 40c ramp start, and the fan flipped 10<->15% every 30
seconds. The ramp is now 44-56c, which puts the drives back on the floor
with 19c of headroom to their 60c limit.

Adds the deadband from fan_speed.sh so the shelf does not chase every
degree once drives do climb into the ramp, with a downward-only periodic
settle so damping cannot leave it permanently loud.

selftest and disks no longer take the serial lock - they do not open the
port, and refusing to run them while the service is up is unhelpful.

The new tests caught a real bug: in `local a=$1 b=$a` bash expands the
right-hand sides before the locals exist, so the held value was silently
empty.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-30 16:52:12 -07:00

181 lines
7.9 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# md1200-fan-control
Temperature-aware fan control for a Dell PowerVault MD1200 disk shelf, driven over the
EMM's serial debug console.
Out of the box an MD1200 runs its fans at a fixed, very loud speed. The EMM firmware
accepts a `_shutup <percent>` command that overrides it — but it forgets the setting
after a few seconds, and it has no idea how hot your drives actually are. This repo
reads drive temperatures on the host and re-sends an appropriate fan speed on a
keepalive loop.
## Hardware you need
The MD1200 EMM exposes its debug console on the **top-left RJ45 port of the left EMM**
(the one labelled for service use, not the SAS ports). It is not Ethernet — it is RS-232
behind an RJ45 jack, so you need the Dell service cable:
**Dell Password Reset / Service Cable — part `MN657`, also sold as `CT109`.**
Same cable is listed for the MD1000 / MD1220 / MD3000 / MD3200 family, so search on any
of those. It terminates in a DB9 serial connector; if your host has no physical serial
port, add any USB-to-DB9 adapter and point the script at the resulting `/dev/ttyUSB*`.
On the machine this was written for, the cable lands on an onboard UART at `/dev/ttyS1`.
Serial settings: **38400 8-N-1**, no flow control.
> Note: Dell's own KB articles list 115200 for MD3xxx/ME3xxx *controllers*. That is a
> different port on different hardware. The MD1200 EMM debug console is 38400, which is
> what this repo uses and what was verified against the real shelf.
Once connected you get a prompt like:
```
BlueDress.106.000 >
```
## Debug commands
There is no `help` — the firmware answers `unknown_cmd` to `help`, `_help` and `?`. The
two commands this project relies on:
| Command | Effect |
|---|---|
| `_shutup <0-100>` | Set fan speed to that percentage. Forgotten if not re-sent. |
| `_temp_rd` | Print the enclosure temperature sensors. |
`_temp_rd` output looks like:
```
BP_1[2] = 30c <- drive backplane
BP_2[3] = 31c <- drive backplane
SIM0[0] = 36c <- enclosure management module
EXP0[4] = 59c <- SAS expander chip, runs hot by design
AVG = 39c
```
Commands are terminated with a bare `\r` (not `\n`).
## What this does
`das_fanctl.sh` runs as a systemd service and loops:
1. Read the temperature of every drive in the shelf with `smartctl`, take the hottest.
2. Interpolate a fan percentage between the low and high thresholds.
3. Send `_shutup <percent>`, and re-send it every 5s so the EMM doesn't revert.
4. Re-read temperatures every 30s.
**Drive temperature, not enclosure air.** The `BP_*` sensors read backplane intake air,
which sat at 30c while the drives themselves were 3239c — it lags what you actually
care about. Drive temps come from `smartctl -n standby`, so a sleeping drive is skipped
rather than spun up just to be measured. If no drive answers (all in standby, smartctl
missing), it falls back to the hottest `BP_*` sensor with its own threshold pair.
`EXP0` is deliberately ignored. The SAS expander idles around 59c by design; including
it in the curve pegs the fans permanently.
## Usage
```
das_fanctl.sh # the service loop (default)
das_fanctl.sh once # one read + set, prints what it did
das_fanctl.sh disks # per-drive temperatures and the hottest
das_fanctl.sh temps # raw _temp_rd output from the shelf
das_fanctl.sh selftest # asserts the parser, the curve, and that drives are readable
```
## Install
The script sources `functions.sh` by absolute path, so it expects to live in
`/root/fan_speed/`:
```sh
install -m 755 das_fanctl.sh functions.sh /root/fan_speed/
mkdir -p /root/fan_speed/log
install -m 644 fan_speed_das.service /etc/systemd/system/
systemctl daemon-reload
systemctl enable --now fan_speed_das.service
```
Check it: `das_fanctl.sh selftest`, then `tail -f /root/fan_speed/log/das_fan.log`.
```
2026-08-24 23:26:03 || DAS disk:39c | Fan Speed:10
```
## Tuning
All knobs are at the top of `das_fanctl.sh`:
| Variable | Default | Meaning |
|---|---|---|
| `PORT` | `/dev/ttyS1` | Serial device the service cable lands on |
| `CHECK_INTERVAL` | `30` | Seconds between temperature readings |
| `KEEPALIVE_INTERVAL` | `5` | How often to re-send `_shutup` |
| `DISK_LOW_TEMPERATURE_THRESHOLD` | `44` | At/below this, run at `LOW_FAN_SPEED` |
| `DISK_HIGH_TEMPERATURE_THRESHOLD` | `56` | At/above this, run at `HIGH_FAN_SPEED` |
| `FAN_SPEED_DEADBAND` | `8` | Hold the current speed until the request moves this far |
| `SETTLE_INTERVAL` | `300` | Allow a downward settle this often |
| `LOW_FAN_SPEED` | `10` | Percent |
| `HIGH_FAN_SPEED` | `60` | Percent |
| `BP_*_THRESHOLD` | `30` / `45` | Fallback curve, backplane air sensors |
**Start the ramp above the drives' normal working range.** This is the single most
common way to make a shelf cycle audibly: if the ramp starts inside the range the drives
already occupy, ordinary drift crosses it and the fans flip every cycle. The curve is
~4%/degC, so one degree moves the fan noticeably.
Worked example: the original 4050c was sized for 8×2TB drives idling at 3239c. Retiring
those for 4×8TB + a 16TB moved the hottest drive to 4041c — exactly the old ramp start —
and the fan flipped 10↔15% every 30 seconds (18 samples at 10, 22 at 15). Moving the ramp
to 4456c put the drives back on the floor: 11 consecutive samples at 10%, and they still
have 19c of headroom to their 60c limit.
`FAN_SPEED_DEADBAND` damps what remains, so once drives do climb into the ramp it does not
chase every degree. A settle is permitted every `SETTLE_INTERVAL`, downward only —
a symmetric deadband would catch the fan on the way up and never let it back down.
`KEEPALIVE_INTERVAL` is inherited from the 5s cadence the original setup used, not
measured. How fast the EMM actually reverts is unknown; if the fans audibly surge
between keepalives, lower it.
## Notes
- Only one process may talk to the serial port. The script takes an exclusive `flock` on
`/run/das_fanctl.lock` and exits rather than interleaving garbage with another writer.
Detach `attachDAS.sh`'s `screen` session before starting the service.
- **`DISK_GLOB` must name the shelf's HBA on any host with more than one.** The default
`*-sas-exp*-lun-0` means "behind a SAS expander", which is not the same as "in the
shelf": a server's own backplane is frequently behind an expander too. On `iz-pve0` the
internal drives sit on `pci-0000:02:00.0` and the shelf on `pci-0000:04:00.0`, so the
default glob matched all 17 drives and would have set the shelf's fans from the
server's internal drive temperatures. Set
`Environment=DISK_GLOB=/dev/disk/by-path/*04:00.0*-lun-0` in the unit.
- **The server's own fan controller needs the mirror-image setting.** Whichever host the
shelf is plugged into must set `DISK_EXCLUDE_PATTERN` to that same HBA in
`fan_speed.service`, or the shelf's drives drive the *server* fans as well. Moving the
shelf between hosts means moving both settings.
- `PORT` is per host too. Check which UART actually answers rather than assuming:
`grep -v uart:unknown /proc/tty/driver/serial` lists the real ones, then send
`_temp_rd` to each and watch for the `BlueDress` prompt.
## Files
| File | |
|---|---|
| `das_fanctl.sh` | The fan controller |
| `fan_speed_das.service` | systemd unit for it |
| `functions.sh` | Only `calculate_interpolated_fan_speed` is used here — the rest is iDRAC/IPMI |
| `attachDAS.sh` | Drop into an interactive `screen` session on the shelf console |
| `get_das_temp.sh` | Superseded by `das_fanctl.sh temps` — it never read the reply back |
| `log_rotate.txt` | logrotate snippet for the log directory |
## Credit
`functions.sh` comes from the
[Dell iDRAC fan controller](https://github.com/tigerblue77/Dell_iDRAC_fan_controller_Docker)
project; this repo only uses its `calculate_interpolated_fan_speed`. Prior art on the MD1200 console specifically:
[tonybaltovski/md1200-reduce-fans-systemd](https://github.com/tonybaltovski/md1200-reduce-fans-systemd)
and [iamjoshgilman/md1200-fan-controller](https://github.com/iamjoshgilman/md1200-fan-controller).