mirror of
https://github.com/python-kasa/python-kasa.git
synced 2024-12-22 11:13:34 +00:00
Merge pull request #5 from smaggard/add-hs200
Adding in support for the HS200 Wall switch referencing issues (#4)
This commit is contained in:
commit
9c39249b99
@ -9,6 +9,7 @@ import codecs
|
||||
import json
|
||||
import datetime
|
||||
import sys
|
||||
import re
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
@ -104,7 +105,7 @@ class SmartPlug(object):
|
||||
False if command is not successful or the switch doesn't support energy metering
|
||||
Dict with the current readings
|
||||
"""
|
||||
if self.model == 100:
|
||||
if self.model != 110:
|
||||
return False
|
||||
|
||||
response = self._send_command('{"emeter":{"get_realtime":{}}}')
|
||||
@ -126,7 +127,7 @@ class SmartPlug(object):
|
||||
False if command is not successful or the switch doesn't support energy metering
|
||||
Dict where the keys represent the days, and the values are the aggregated statistics
|
||||
"""
|
||||
if self.model == 100:
|
||||
if self.model != 110:
|
||||
return False
|
||||
|
||||
response = self._send_command('{"emeter":{"get_daystat":{"month":' + str(month) + ',"year":' + str(year) + '}}}')
|
||||
@ -152,7 +153,7 @@ class SmartPlug(object):
|
||||
False if command is not successful or the switch doesn't support energy metering
|
||||
Dict - the keys represent the months, the values are the aggregated statistics
|
||||
"""
|
||||
if self.model == 100:
|
||||
if self.model != 110:
|
||||
return False
|
||||
|
||||
response = self._send_command('{"emeter":{"get_monthstat":{"year":' + str(year) + '}}}')
|
||||
@ -175,7 +176,7 @@ class SmartPlug(object):
|
||||
True: Success
|
||||
False: Failure or not supported by switch
|
||||
"""
|
||||
if self.model == 100:
|
||||
if self.model != 110:
|
||||
return False
|
||||
|
||||
response = self._send_command('{"emeter":{"erase_emeter_stat":null}}')
|
||||
@ -187,7 +188,7 @@ class SmartPlug(object):
|
||||
|
||||
def current_consumption(self):
|
||||
"""Get the current power consumption in Watt."""
|
||||
if self.model == 100:
|
||||
if self.model != 110:
|
||||
return False
|
||||
|
||||
response = self.get_emeter_realtime()
|
||||
@ -252,10 +253,5 @@ class SmartPlug(object):
|
||||
def _identify_model(self):
|
||||
"""Query sysinfo and determine model"""
|
||||
sys_info = self.get_info()
|
||||
|
||||
if sys_info["system"]["get_sysinfo"]["model"][:5] == 'HS100':
|
||||
model = 100
|
||||
elif sys_info["system"]["get_sysinfo"]["model"][:5] == 'HS110':
|
||||
model = 110
|
||||
|
||||
model = re.sub('HS', '', sys_info["system"]["get_sysinfo"]["model"][:5])
|
||||
return model
|
||||
|