@@ -7,6 +7,8 @@ Right-click the **Looking Glass (IDD)** icon in the Windows notification area
and select **Open configuration**. The icon and its tooltip also show whether
the driver is using GPU acceleration or software processing.
.. _idd_display_modes:
Display modes
-------------
@@ -22,15 +24,37 @@ for the Looking Glass monitor.
* Enable **prefer** on the mode that Windows should prefer. Only one mode can
be preferred.
Refresh rates may contain up to three decimal places. For example, enter
Refresh rates may contain up to three decimal places. For example, you can enter
``119.970`` rather than rounding it to 120 Hz. Accepted values range from
23.900 Hz to 1000.000 Hz. Width may range from 640 to 16384 pixels and height
from 480 to 16384 pixels.
Edits to the mode list are not applied immediately. Select **Save & reload
driver** when the list is ready. This saves the list, removes and recreates the
virtual monitor, and can make the display blink briefly. **Revert** discards
unsaved mode and default-refresh changes.
Edits to the mode list are not applied immediately, you must select **Save &
reload driver** when the list is ready. This saves the list, then removes and
recreates the virtual monitor, and can make the display blink briefly.
**Revert** discards unsaved mode and default-refresh changes.
.. _idd_mode_culling:
Modes that do not fit in shared memory
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
At startup, the IDD removes modes that cannot fit in the configured IVSHMEM
region. If every suitable mode is filtered, the monitor cannot start. A
dynamic resolution request that is too large is refused and the helper reports
the minimum power-of-two IVSHMEM size needed.
To allow for modes that do not currently fit, increase the IVSHMEM size in the
VM configuration and restart the VM. The IDD reads the new capacity when it
starts; another helper reload is not normally required. Allocating more shared
memory than required does not improve performance; it only reserves additional
host RAM.
.. seealso::
:ref:`libvirt_determining_memory`
.. _idd_refresh:
Default refresh
---------------
@@ -39,14 +63,16 @@ Default refresh
resolution. It also supplies the refresh rate when **Load default** rebuilds
the standard mode list.
Changing this value does not rewrite refresh rates already saved in the normal
Changing this value does not update refresh rates already saved in the normal
mode list. On reload, an existing dynamic mode keeps its resolution and adopts
the new default refresh rate.
The client option ``win:setGuestRes`` enables automatic dynamic resolution
requests when the client window changes size. The default is enabled when the
server in the guest supports it. Press the client's escape key together with
``=`` to request the current window resolution manually.
server in the guest supports it. Press :kbd:`ScrLk` + :kbd:`=` to request the
current window resolution manually.
.. _idd_preferences:
Preferences
-----------
@@ -79,7 +105,9 @@ Force indirect copy
a CPU copy and significantly reduces throughput. It takes precedence over
the direct-copy preference and requests a driver reload when changed.
Unlike mode-list edits, preference checkboxes are saved when clicked.
Unlike mode-list edits, preference checkboxes are automatically saved.
.. _idd_software_processing:
Software processing
-------------------
@@ -88,16 +116,3 @@ If no suitable Windows render adapter is available, the IDD can use software
processing. This provides a display but is slower, cannot provide predictable
high-rate cadence and is limited to SDR. Check the IDD log to see which render
adapter was selected and whether software processing is active.
Modes that do not fit in shared memory
--------------------------------------
At startup the IDD removes modes that cannot fit in the configured IVSHMEM
region. If every suitable mode is filtered, the monitor cannot start. A
dynamic resolution request that is too large is refused and the helper reports
the minimum power-of-two IVSHMEM size needed.
Increase the IVSHMEM size in the VM configuration and restart the VM. The IDD
reads the new capacity when it starts; another helper reload is not normally
required. Allocating more shared memory than required does not improve
performance; it only reserves additional host RAM.