Some Kasa IoT devices accept the account e-mail with `kasaSetup`
instead of the account password over KLAP. python-kasa only tries that
password with the default Kasa account, so these devices fail to
authenticate even with the correct account credentials.
This PR checks the account e-mail with the setup password locally
against handshake1, after the supplied credentials, without an extra
request.
In details:
- Try the e-mail as given, then trimmed and lowercased as the Kasa app
sends it.
- Keep the fallbacks in one ordered list, with an explicit `save_hash`
flag controlling hash persistence.
- Save only a matching account/setup hash as `credentials_hash`, so
stored configs can reconnect without the e-mail.
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
This centralizes the response budgets in
`IotDevice.max_device_response_size` and removes the bulb override:
- KLAP: 2048 for every IoT device.
- Other transports: 4096 for bulbs and light strips, 16 KiB for other
IoT devices.
Some tests leave the `kasa` logger at a different level or rename devices
in shared fixture data. Later log assertions and device dump comparisons
then pass or fail depending on the test order.
This PR restores logger levels through `caplog` and renames devices on
copies, so the affected tests pass independently of their order.
In details:
- Use `caplog.set_level` for tests that change the `kasa` logger, and
remove an unused logger override.
- Add an autouse fixture that restores any changed logger levels and
fails the test with a pointer to `caplog.set_level`.
- Rename README devices on deep copies of the fixture data.
- Cover KLAP handshake debug logging explicitly, instead of relying on
an earlier test leaving DEBUG enabled.
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
Some IoT devices respond over KLAP with a plain `200 OK` html page
instead of a proper response when the response would be too large to
construct, causing a "not a multiple of the block length" decryption
error (e.g., KS200M in #1828).
This PR lowers the maximum response size to 2048 bytes for IoT devices
using KLAP, so that the update is split into multiple smaller requests
like it is already done for bulbs.
In details:
- `IotDevice.max_device_response_size` returns 2048 over KLAP. Bulbs
keep 4096 and XOR devices keep 16 KiB.
- `KlapTransport` checks the response length and signature before
decrypting, and raises a `KasaException` telling what was wrong
instead of the decryption error.
Fixes#1828
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
type annotations and parameter type annotations to
all test functions and helper functions across the 5 transport test
files. This enables mypy to check function bodies, catching type errors
that were previously hidden.
* Transport tests under tests/transports/
* Protocol tests under tests/protocols/
* IOT tests under iot/
* Plus some minor cleanups, most code changes are related to splitting