2024-11-09 07:16:41 +00:00
{
2024-11-22 07:59:17 +00:00
"cnCloud" : {
"get_info" : {
"binded" : 1 ,
"cld_connection" : 1 ,
"err_code" : 0 ,
"fwDlPage" : "" ,
"fwNotifyType" : -1 ,
"illegalType" : 0 ,
"server" : "n-devs.tplinkcloud.com" ,
"stopConnect" : 0 ,
"tcspInfo" : "" ,
"tcspStatus" : 1 ,
"username" : "#MASKED_NAME#"
} ,
"get_intl_fw_list" : {
"err_code" : 0 ,
"fw_list" : [
{
"fwLocation" : 0 ,
"fwReleaseDate" : "2024-06-19" ,
"fwReleaseLog" : "Modifications and Bug Fixes:\n1. Added \"Hold on\" feature, now you can quickly double-click the switch to keep it on without being affected by the Smart Control rules.\n2. Fixed a bug where Motion & Dark rules could still be triggered under bright light conditions.\n3. Fixed some minor bugs." ,
"fwReleaseLogUrl" : "undefined yet" ,
"fwTitle" : "Hi, a new firmware with bug fixes and performance improvement is available for your KS200M." ,
"fwType" : 2 ,
"fwUrl" : "http://download.tplinkcloud.com/firmware/KS200M_FCC_1.0.12_Build_240507_Rel.143458_2024-05-07_14.37.42_1718767325443.bin" ,
"fwVer" : "1.0.12 Build 240507 Rel.143458"
}
]
}
} ,
"schedule" : {
"get_next_action" : {
"err_code" : 0 ,
"type" : -1
} ,
"get_rules" : {
"enable" : 1 ,
"err_code" : 0 ,
"rule_list" : [ ] ,
"version" : 2
}
} ,
2024-11-09 07:16:41 +00:00
"smartlife.iot.LAS" : {
2024-11-22 07:59:17 +00:00
"get_adc_value" : {
"err_code" : 0 ,
"type" : 2 ,
"value" : 0
} ,
2024-11-09 07:16:41 +00:00
"get_config" : {
"devs" : [
{
"dark_index" : 0 ,
"enable" : 1 ,
"hw_id" : 0 ,
"level_array" : [
{
"adc" : 390 ,
"name" : "cloudy" ,
"value" : 15
} ,
{
"adc" : 300 ,
"name" : "overcast" ,
"value" : 12
} ,
{
"adc" : 222 ,
"name" : "dawn" ,
"value" : 9
} ,
{
"adc" : 222 ,
"name" : "twilight" ,
"value" : 9
} ,
{
"adc" : 111 ,
"name" : "total darkness" ,
"value" : 4
} ,
{
"adc" : 2400 ,
"name" : "custom" ,
"value" : 97
}
] ,
"max_adc" : 2450 ,
"min_adc" : 0
}
] ,
"err_code" : 0 ,
"ver" : "1.0"
2024-11-22 07:59:17 +00:00
} ,
"get_current_brt" : {
"err_code" : 0 ,
"value" : 0
} ,
"get_dark_status" : {
"bDark" : 1 ,
"err_code" : 0
2024-11-09 07:16:41 +00:00
}
} ,
"smartlife.iot.PIR" : {
2024-11-22 07:59:17 +00:00
"get_adc_value" : {
"err_code" : 0 ,
"value" : 2025
} ,
2024-11-09 07:16:41 +00:00
"get_config" : {
"array" : [
80 ,
50 ,
20 ,
0
] ,
"cold_time" : 15000 ,
"enable" : 1 ,
"err_code" : 0 ,
"max_adc" : 4095 ,
"min_adc" : 0 ,
2024-11-22 07:59:17 +00:00
"trigger_index" : 2 ,
2024-11-09 07:16:41 +00:00
"version" : "1.0"
}
} ,
"system" : {
"get_sysinfo" : {
"active_mode" : "none" ,
"alias" : "#MASKED_NAME#" ,
"dev_name" : "Smart Light Switch with PIR" ,
"deviceId" : "0000000000000000000000000000000000000000" ,
"err_code" : 0 ,
"feature" : "TIM" ,
"hwId" : "00000000000000000000000000000000" ,
"hw_ver" : "1.0" ,
"icon_hash" : "" ,
"latitude_i" : 0 ,
"led_off" : 0 ,
"longitude_i" : 0 ,
"mac" : "54:AF:97:00:00:00" ,
"mic_type" : "IOT.SMARTPLUGSWITCH" ,
"model" : "KS200M(US)" ,
"next_action" : {
"type" : -1
} ,
"obd_src" : "tplink" ,
"oemId" : "00000000000000000000000000000000" ,
"on_time" : 0 ,
"relay_state" : 0 ,
2024-11-22 07:59:17 +00:00
"rssi" : -38 ,
2024-11-09 07:16:41 +00:00
"status" : "new" ,
"sw_ver" : "1.0.10 Build 221019 Rel.194527" ,
"updating" : 0
}
}
}