mirror of
https://github.com/brezlord/iDRAC7_fan_control.git
synced 2024-11-25 15:07:25 +00:00
Update README.md
This commit is contained in:
parent
ffbe67aaee
commit
2428d4b524
17
README.md
17
README.md
@ -4,3 +4,20 @@ If the inlet temperature is above 35deg C enable iDRAC dynamic control and exit
|
||||
If inlet temp is below 35deg C set fan control to manual and set fan speed to predetermined value.
|
||||
The tower servers T320, T420 & T620 inlet temperature sensor is after the HDDs so temperature will
|
||||
be higher than the ambient temperature.
|
||||
|
||||
You can change the temperature set points in the script to sute your needs.
|
||||
|
||||
I use this script on a Dell T320 running TrueNAS 12 and it work great. You will need to create a data
|
||||
set for the script to recide in and make it excicutable, run chmod +x /mnt/tank/fan_control/fan_control.sh
|
||||
this assumes that you have a pool called tank and an dataset named fan_control.
|
||||
|
||||
You can test the script by running ./fan_sontrol.sh from the scrips directory. If it is working you should
|
||||
get an output similar to this;
|
||||
|
||||
Date 04-09-2020 10:24:52
|
||||
--> iDRAC IP Address: 192.168.40.140
|
||||
--> Current Inlet Temp: 22
|
||||
--> Temperature is below 35deg C
|
||||
--> Disabled dynamic fan control
|
||||
|
||||
--> Setting fan speed to 20%
|
||||
|
Loading…
Reference in New Issue
Block a user